Choosing 24-Fiber MPO/MTP Cabling for 40/100G Migration

In 2002, the IEEE ratified the 802.3ae standard for 10GbE over duplex fibers (one fiber transmits and the other receives) terminated with duplex LC-style connectors and vertical cavity surface-emitting laser (VCSEL) transceivers. With the increasing need for high speed data transmission, in 2010, the IEEE ratified the 802.3ba standard for 40/100G to satisfy this demand. Similar to how transportation highways are scaled to support increased traffic with multiple lanes at the same speed, the 40/100G standards use parallel optics, or multiple lanes of fiber transmitting at the same speed. Running 40G requires 8 fibers, with 4 fibers each transmitting at 10Gbit/s and 4 fibers each receiving at 10Gbit/s. Running 100G requires a total of 20 fibers, with 10 transmitting at 10Gbit/s and 10 receiving at 10Gbit/s. Both scenarios call for high-density MPO-style connectors, which can be either 12-fiber or 24-fiber. However, 24-fiber MPO/MTP cabling is often considered to be the better solution for 40/100G migration. Why? Reading this post and you will get the reasons.

12-Fiber and 24-Fiber MPO/MTP Cabling
A 12-fiber MPO/MTP connector is used for 40G Ethernet. Among the 12 fibers, only 8 optical fibers are required—4 for Tx and 4 for Rx, and each channel has a transmission rate of 10Gbps (typically 40G applications use only the 4 left and 4 right optical fibers of the 12-fiber MPO/MTP connector, while the inner 4 optical fibers are left unused). To run 100GbE, there are two solutions. One is to use two 12-fiber MPO/MTP connectors—one transmitting 10Gbit/s on 10 fibers and the other receiving 10Gbit/s on 10 fibers. The other solution is to use a 24-fiber MPO/MTP connector—20 fibers in the middle of the connector transmitting and receiving at 10Gbit/s and the 2 top and bottom on the left and right unused. 12-fiber can be both used for 40/100G solutions, but why said the 24-fiber is better than 12-fiber? The following part will explain in details. The image below shows different construction of 12-fiber and 24-fiber MPO/MTP.

12-fiber vs. 24-fiber

Why Is the 24-Fiber the Right Migration Path to 40/100G?
Fiber Utilization to the Extreme
Using 24-fiber trunk cables with 24-fiber MPO/MTP connectors on both ends to connect from the back of the switch panel to the equipment distribution area can utilize the fibers to the extreme. As we have mentioned above, 40G will uses 8 fibers (4 Tx and 4 Rx) of the total 12-fiber trunk cable with 12-fiber MPO/MTP connectors, leaving 4 fibers unused. Nevertheless, when three 40G links are using three separate 12-fiber trunk cables, it will result in a total of 12 unused fibers, or 4 fibers unused for each trunk, which can be a waste. With the use of 24-fiber, running three 40G links will use all 24 fibers of the trunk cable, which recoups 33 percent of the fibers that could be lost with 12-fiber trunk cables, providing a much better return on investment. For 100G applications, which require 20 fibers (10 Tx and 10 Rx), a 24-fiber trunk cable can provide a single 100G link instead of using two 12-fiber trunk cables.

Spacing Saving
With more and more patch cables and optical equipment used in data centers, space is a premium. Using 24-fiber trunk cable will cause less cable congestion in already-crowded pathways, which can save more space and make cable management easier. For example, for a 40G application, it takes three 12-fiber trunk cables to provide the same number of links as a single 24-fiber trunk cable which can take about 1.5 times more pathway space.

Increasing Fiber Density
With today’s large core switches occupying upwards of one-third of an entire rack, density in fiber switch panels is critical. 24-fiber MPO connectors offer a small footprint which can ultimately provide increased density in fiber panels at the switch location.

Cost Effective
The 24-fiber data center fiber trunking and interconnect solution offers a simple and cost effective migration path from 10G-40G-100G, providing future-readiness for three generations of active equipment. With 24-fiber trunk cables effectively supporting all three applications (shown in the following picture), there is no need to recable the pathway from the back of the switch panel to the equipment distribution area.

24-fiber for 10, 40 and 100G applications

Conclusion
With increasing concerns about the cost to upgrade and the complexity involved, data center managers need a solution that simplifies the process and provides better return on investment, while meeting both current and future needs. Taking the advantages of maximum fiber utilization, space and cost saving and high density, it is no doubt that 24-fiber MPO/MTP cabling is better solution for 40/100G migration.

2016年10月13日星期四

Which Cable Jacket Is Best for Your Application?

When buying bulk cables or cable assemblies, you’re probably concerned about things like conductor AWG size, shielding for EMI/RFI, connector molding construction, etc. Why would you spare a thought to the jacket that just goes around the conductors? Actually, cable jacket is much more important than you may think. Choosing the wrong cable jacket can have implications in a range of things, from extending the life of your cable, to using the cable in the field. The following part will briefly introduce several commonly used cable jackets for your references.

The Importance of Cable Jacket
The cable jacket is the first line of mechanical, moisture, flame and chemical defense for a cable. More specifically, the jacket provides protection for the shielding and conductors. It protects the cable from mechanical damage during and after installation. Jackets are not intended to replace cable armors, but they can provide a fairly high level of moisture and chemical protection along with UV and ozone protection. The following image shows the structure of optical cable.

structure of cable

Commonly Used Cable Jackets
PVC
PVC (polyvinyl chloride) is the most widely used nonmetallic jacketing material in the wire and cable industry. Starting in 1935, when it first became available, the use of PVC grew rapidly because of its low cost, easy processing and excellent combination of overall properties including fire and chemical resistance. Nevertheless this kind of jacket also has shortcomings. For example, PVC is a thermoplastic material, so it cannot take high temperature. In industries that handle large amounts of heated material, or where there are the possibilities of excessive heat, the use of PVC should be avoided, because of its tendency to melt or deform when heated to a high temperature.

LSZH
Increasing concern for worker safety and electronic circuit life circle is driving demand for low-smoke,zero-halogen (LSZH) material. LSZH is composed of thermoplastic or thermoset compounds which will emit limited smoke and no halogen when wires or patch cables are damaged by fire or a short circuit fault. This type of jacket is typically used in poorly ventilated areas such as aircraft, rail cars, or ships. It is becoming very popular and, in some cases, a requirement where there is a need for the protection of people and equipment from toxic and corrosive gas.

PUR
Polyurethane, also referred to as PUR, is a thermoplastic material, commonly used in harsh environment. PUR is resistant to swelling and degradation when exposed to water for a long period of time, making it suitable for undersea equipment, like submarine cables. Besides, its flexibility and hardness allow it become a useful compound for isolating electronic components from vibration and shock. However, the only demerit of PUR jacket is that it is more expensive than other types of common jackets.

EPR
EPR (ethylene propylene rubber) is a chemically cross-linked, thermosetting high-temperature rubber insulation. It has excellent electrical properties combined with outstanding thermal stability and flexibility. It can also withstand the cold temperature down to -60 Celsius degree. With fairly good high-temperature characteristics overall, when formulated correctly, EPR can be rather flame retardant as well.

Silicon
As a form of synthetic rubber, silicon has excellent electrical properties plus ozone resistance, low moisture, weather and radiation resistance. While silicon rubber burns slowly, it forms a non-conductive ash which, in some cases, can maintain the integrity of the electrical circuit. Silicon jacket is typically used for applications where lots of wire bending are required.

Conclusion
Cable jacket is not as simple as you think. When you choose patch cables or coppers, you should also take jacket factor into consideration. There are various types of cable jackets available on the market and each of them can be used in different circumstances. After reading this passage, hope you can choose the best one for your applications.